ALN Implants chirurgicaux

The removal and/or repositioning kits of the ALN vena cava filters with and without hook

For 30 years our company ALN has been monitoring technological advances and the evolving needs of the medical market, and is committed to a strong innovative approach, through the design of variations of vena cava filters as well as removal and/or repositioning kits.

2013 is a strong year for ALN surgical implants, the leading manufacturer and distributor in France of medical devices aimed at preventing pulmonary embolism. It is marked by 3 significant launches:

 
  • The ALN vena cava filter with hook
  • The popliteal approach (check availability in your country with your distributor)

  • The removal and/or repositioning kit 2 in 1 which increases the range of our removal and/or repositioning kits.

     

     

     

     

The removal and/or repositioning kits of the ALN vena cava filters with and without hook

ALN vena cava filter removal and/or repositioning kits with and without hook

A removal procedure only by jugular approach

 

The ALN Vena Cava Filter Removal and/or Repositioning Kits are designed to remove ALN Vena Cava Filters with and without a hook, when a patient no longer has an indication requiring filtration. Similarly, they are indicated if a repositioning of the ALN vena cava filter is necessary.

 

The device is available in three options, the choice of use of which depends on the clinical situation:

  • The removal and/or Repositioning Kit / ALN Straight RS, which is used when the filter head is in the lower vena cava axis.
  • Angulated removal and/or Repositioning Kit / ALN Pre-curved RS, which is recommended if the filter head is tilted from the lower vena cava axis.
  • The 2 in 1 / ALN 2 in 1 RS removal and/or repositioning kit, which provides the ability to change the clamp angulation according to the position of the ALN filter in the inferior vena cava

Features of the extraction and/or repositioning kit clamp

  • Made of 316 LVM stainless steel
  • Its consists of 8 strands of different lengths
  • Once the filter head is bumped into the clamp by the push of tht 9F catheter, the ALN vena cava filter with and without hook is secure.
  • Compatible with all ALN vena cava filter product code numbers.

ALN Removal and/or Repositioning Kit, Composition


  • A pincer catheter of the chosen reference.
  • A dilator
  • A 9F introducer sheath.
  • A puncture needle
  • A " J " Tip guidewire (0.035).


Product Codes

  Product Code Introducer Sheath
French size (ID) Length (mm)
ALN Vena Cava Filter Removal and/or Repositioning Kit
only by Jugular approach
ALN Straight RS FT.902010 9 570
ALN Pre-Curved RS FT.902010/VS2 9 570
ALN 2 IN 1 RS RK-2010 9 610

Access technical documentation

Partager cette page sur les réseaux sociaux